NETIO PowerBOX 3Px electrical socket with 3 outputs and LAN connectivity
  • NETIO PowerBOX 3Px electrical socket with 3 outputs and LAN connectivity

NETIO PowerBOX 3Px electrical socket with 3 outputs and LAN connectivity

$282.00

NETIO PowerBOX 3Px is a power socket device with 3 outputs controlled over a LAN. Each output can be switched off and on over the web, the NETIO cloud service, or with a mobile app. Open API enables integration into 3rd party systems using a wide range of protocols (http JSON, Modbus/ TCP, SNMP, MQTT, Telnet, ..). Each of the three power sockets can be independently controlled from the product web interface (switched off/on or power-cycled). To switch the outputs on in a sequence, a power-up delay interval can be configured for each output.

Quantity

The NETIO Mobile2 app controls each output individually over LAN (local network) or NETIO Cloud. 

NETIO Cloud is a SSL-secured service for controlling the outputs from anywhere (Web or Cloud API).

Open API allows controlling the outputs over the network using various protocols (http XML/JSON, Modbus/TCP, MQTT, SNMP, Telnet and more... ).

AV drivers make it easy to connect NETIO sockets to professional Audio/Video systems such as Neets, Crestron, Control4 and more.

The Scheduler function switches outputs on and off at configured times. It works locally, even without Internet connection.

  • 3x output (electrical socket) 
  • Each output can be switched on and off 
  • LAN (Ethernet)
  • Open API (10 protocols, M2M API) 
  • ZVS – Zero Voltage Switching 
  • Service: NETIO Cloud 
  • Mobile application: NETIO Mobile2

PDU
100 Items

Data sheet content

PDU

3. Electrical load
ZVS (Zero Voltage Switching)
3. Fuse
Integrated , non-resettable
3. Internal consumption
Max 2W
3. Maximum line breaker capacity
C16A
3. Network interfaces
1x Ethernet RJ-45 10/100 Mbit/s
3. Power
100-240 V; 50/60 Hz; 16 A
3. Power Output relays
Micro-disconnection (µ) (resistive load) , SPST-NO 1E5 switching cycles , max. 1.5 kV pulse voltage Switch heat and fire resistance class 1
3. Surge protection
Type 3 (CAT III)
3. Switched outputs
16 A in total / 16 A each output

16 other products in the same category

Specifications

PDU

3. Electrical load ZVS (Zero Voltage Switching)
3. Fuse Integrated, non-resettable
3. Internal consumption Max 2W
3. Maximum line breaker capacity C16A
3. Network interfaces 1x Ethernet RJ-45 10/100 Mbit/s
3. Power 100-240 V; 50/60 Hz; 16 A
3. Power Output relays Micro-disconnection (µ) (resistive load), SPST-NO 1E5 switching cycles, max. 1.5 kV pulse voltage Switch heat and fire resistance class 1
3. Surge protection Type 3 (CAT III)
3. Switched outputs 16 A in total / 16 A each output