8100 hopf time server
  • 8100 hopf time server
  • 8100 hopf time server

8100 hopf time server

$0.00

The 8100 product series are modular time reference systems supporting the Global Navigation Satellite Systems (GNSS) GPS, Galileo, GLONASS, and BeiDou for precise and reliable time synchronization at highly competitive pricing which is especially well suited for critical infrastructure applications The 8100 product series time reference systems have been designed for synchrophasor and substation applications with high requirements in terms of flexibility, availability and the support of a wide variety of time synchronization standards. The modular system design features easy spare part management and minimum mean time to repair (MTTR) with all parts / extension boards supporting hot-plug capability. 

Quantity

Configurator



Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

next







next







next


Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt
Relay outputs Board
Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

next







next











next


Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

Thumbnail Alt

finish

components list


IRIG-B expansion board
Not selected
DCF77 function
Not selected
Protocol function
Not selected
In-out function
Not selected
Crystal function
Not selected
GPS-GNSS function
Not selected
Power supply function
Not selected
Must-have accessories
Not selected
Discount: $
Product with this customization

$0.00

x
You must fill all the customization options before to make the order

The modularity of the system also ensures security of investment if the requirements for the system should change in the future. The system supports both single and dual / redundant power supplies (PSU) to ensure higher availability. Power supplies are available for DC input voltages 24VDC (18 – 36VDC), 48VDC (36 – 76VDC), 110VDC (60 – 160VDC), 300VDC (200 – 400VDC) and wide range AC/DC input voltages 85 – 264VAC (50Hz / 60Hz) / 125 – 250VDC. The DC voltage power supplies feature redundant power inputs for connection of two power sources to a single power supply. In the version with redundant power supplies, the available power supplies can be combined as required. Up to six extension slots are available for time domain controller (time signal input from time source), service consumer boards (time signal output / distribution to customer application), and system management boards.

8100-hopf.jpg

A variety of service consumer boards is available for, among others:

  • Network time synchronization using Network Time Protocol (NTP / SNTP), SIMATIC NET SINEC H1 Time Datagram or IEEE 1588™-2019 Precision Time Protocol (PTP) with support for IEC 61850-9-3:2016 profile for power utility automation and IEEE Std C37.238™-2017 power profile.
  • IRIG-B and DCF77 signal output (demodulated / modulated)
  • Programmable cyclic pulse (PPS, PPM, PPH)
  • Serial time datagram (e. g. hopf Standard, IEC-103, ABB Melody / Freelance, Trimble TSIP, SAT1703 / SICAM RTU)
  • Signal distribution via electrical or fiber-optic signal output

The 8100 product series time domain controller features evaluation of time signals from multiple satellite systems freely configurable for GPS, Galileo, GLONASS and BeiDou. On receiver and firmware level the time domain controller implements consistency checks and statistical tests on features such as automatic gain control (AGC), clock error, signal quality, signal power, propagation delay and the angle of arrival in order to safeguard error-free and leap-free time signal evaluation. In case of signal loss due to antenna failure or identification of time signal mismatch due to jamming or spoofing attacks the time domain controller clock automatically switches to the integrated oscillator holdover ensuring the oscillator dependent freewheeling accuracy. For enhanced availability redundant time domain controller configurations are supported. Time domain controller boards are equipped with an integrated management controller which allows easy configuration and monitoring using the hopf unified management application huma® web edition which features secure access to the system via an intuitive to use state-of-the-art web interface. All field replaceable units integrated into the enclosure can be centrally configured. System configurations may be saved for the whole enclosure or for each individual board separately. The management controller continuously monitors the health status of all integrated boards and components. It collects diagnostic and statistical data for the integrated event log and for real time notification of critical events to external IT management systems using email messaging, SNMP traps or external SYSLOG server. The current demand for the convergence of Information Technologies (IT) and Operational Technologies (OT) in critical infrastructure requires to ensure security and reliability in compliance with regulatory requirements. The modular system design of the 8100 product series allows complete separation of operational / productivity network (e.g. process bus for power utility applications) for enhanced security while allowing complete access to diagnostic data and critical events for the IT network management via the integrated management controller. Role based access control according to the most up-to-date standards safeguards secure access to the management controller by authorized staff. The built-in firewall feature adds even increased security against network-based intrusions by limiting access to the .minimum necessary network connections and services. All configuration files and firmware update packages may be signed by certificates to ensure authenticity and eligibility for application.

time server
100 Items

Data sheet content

Time server

Type of time server
GPS , GPS , Galileo , GLONASS and BeiDou (GNSS)
Power supplies
24VDC (18 – 36VDC) , 48VDC (36 – 76VDC) , 110VDC (60 – 160VDC) , 300VDC (200 – 400VDC) , 85 – 264VAC (50Hz / 60Hz) , 125 – 250VDC , 24VDC (18 – 36VDC) , 48VDC (36 – 76VDC) , 110VDC (60 – 160VDC) , 300VDC (200 – 400VDC) and wide range AC/DC input voltages 85 – 264VAC (50Hz / 60Hz) / 125 – 250VDC
power supplies feature
redundant power inputs for connection of two power sources , redundant power inputs for connection of one power sources , single power supply , DC voltage redundant power inputs
Extension slots
six extension slots
Time Server Protocol
(NTP / SNTP) , PTP , IRIG-B , DCF77 , PPS , PPM , PPH , Serial time datagram , TSIP , SAT1703 / SICAM RTU , fiber-optic signal output , RTP , NTP / SNTP , SIMATIC NET SINEC H1 , IEEE 1588™ , PTP , IEC 61850-9-3:2016 , IEEE Std C37.238™-2017 , IRIG-B , DCF77 (demodulated / modulated) , PPS , PPM , PPH , Serial time datagram , IEC-103 , ABB Melody , Trimble TSIP , SAT1703 / SICAM RTU , fiber-optic signal output
oscillator
OCXO , TCXO , OCXO HPFS , OCXO HPFS , TCXO , OCXO
Installation Method
1U fully modular subrack for 19-inch rack mounting
components type
hot-plug , Normal - without hot-plug

Specifications

Time server

Type of time server GPS, GPS, Galileo, GLONASS and BeiDou (GNSS)
Power supplies 24VDC (18 – 36VDC), 48VDC (36 – 76VDC), 110VDC (60 – 160VDC), 300VDC (200 – 400VDC), 85 – 264VAC (50Hz / 60Hz), 125 – 250VDC, 24VDC (18 – 36VDC), 48VDC (36 – 76VDC), 110VDC (60 – 160VDC), 300VDC (200 – 400VDC) and wide range AC/DC input voltages 85 – 264VAC (50Hz / 60Hz) / 125 – 250VDC
power supplies feature redundant power inputs for connection of two power sources, redundant power inputs for connection of one power sources, single power supply, DC voltage redundant power inputs
Extension slots six extension slots
Time Server Protocol (NTP / SNTP), PTP, IRIG-B, DCF77, PPS, PPM, PPH, Serial time datagram, TSIP, SAT1703 / SICAM RTU, fiber-optic signal output, RTP, NTP / SNTP, SIMATIC NET SINEC H1, IEEE 1588™, PTP, IEC 61850-9-3:2016 , IEEE Std C37.238™-2017 , IRIG-B , DCF77 (demodulated / modulated), PPS, PPM, PPH , Serial time datagram, IEC-103, ABB Melody , Trimble TSIP, SAT1703 / SICAM RTU, fiber-optic signal output
oscillator OCXO, TCXO, OCXO HPFS, OCXO HPFS, TCXO, OCXO
Installation Method 1U fully modular subrack for 19-inch rack mounting
components type hot-plug, Normal - without hot-plug