System 7001(RC)-Slave time server 7001
  • System 7001(RC)-Slave time server 7001
  • System 7001(RC)-Slave time server 7001
  • System 7001(RC)-Slave time server 7001
  • System 7001(RC)-Slave time server 7001

System 7001(RC)-Slave time server 7001

$3,960.00

System 7001(RC)-Slave time server is a modular system that is produced in 3 units. It has a keyboard and a wide screen, and it is used in the mater clock system for time synchronization. This system has master/slave capability and supports wide protocols such as IRIG-B, NTP, PTP and DCF77. With additional NTP module, this master clock becomes an accurate time server for computer networks. It supports a maximum of 14 slots.

Quantity

Sub-Master Clock System 7001(RC)-Slave

System 7001(RC)-Slave is a modular system that can be synchronized in connection with an appropriate synchronisation board and/or hardware input via the below stated signals:

  • Serial hopf Master/Slave string provided by a hopf Master Clock
  • DCF77 pulse (1Hz)
  • DCF77 antenna simulation (77.5kHz)
  • IRIG-B
  • NTP/SNTP
  • Precision Time Protocol (PTP) according to IEC 1588

Basically it consists of the following components:

Sub-Master Base System 7001(RC)-Slave consisting of

19" rack (3U/84HP) for mounting into cabinets

Clock board 7020RC-Slave

Display and keypad

Power supply

Max. 15 slots (3U/4HP) for implementation of function boards

Prepared extension slot for LAN Management Board 7052RC

Depending on the used signal and signal level for the synchronisation:

Synchronisation boards and/or additional hardware input

NTP Stratum 1 Time Server

By implementation of NTP LAN Board(s) 7273(RC) or NTP LAN Board(s) 7274(RC) System 7001(RC) becomes a highly accurate NTP Stratum 1 Time Server for synchronization of computers and industrial networks.

Master Clock
100 Items

Data sheet content

Time server

Type of time server
GPS
Power supplies
48VDC (36 – 76VDC) , 110VDC (60 – 160VDC) , 85 – 264VAC (50Hz / 60Hz)
power supplies feature
redundant power inputs for connection of two power sources , redundant power inputs for connection of one power sources , single power supply , DC voltage redundant power inputs
Extension slots
Over 10 extension slots
Time Server Protocol
(NTP / SNTP) , PTP , IRIG-B , DCF77 , PPS , PPM , PPH , Serial time datagram , fiber-optic signal output
oscillator
OCXO , TCXO , OCXO HPFS , TCXO , OCXO
Installation Method
3U-Version
components type
hot-plug
Master Clock
Yes

Specifications

Time server

Type of time server GPS
Power supplies 48VDC (36 – 76VDC), 110VDC (60 – 160VDC), 85 – 264VAC (50Hz / 60Hz)
power supplies feature redundant power inputs for connection of two power sources, redundant power inputs for connection of one power sources, single power supply, DC voltage redundant power inputs
Extension slots Over 10 extension slots
Time Server Protocol (NTP / SNTP), PTP, IRIG-B, DCF77, PPS, PPM, PPH, Serial time datagram, fiber-optic signal output
oscillator OCXO, TCXO, OCXO HPFS, TCXO, OCXO
Installation Method 3U-Version
components type hot-plug
Master Clock Yes