6844(RC) modular GPS system
  • 6844(RC) modular GPS system
  • 6844(RC) modular GPS system
  • 6844(RC) modular GPS system
  • Time server 6844 Hopf

6844(RC) modular GPS system

$4,300.00

System 6844 (RC) is a semi-modular with integrated GPS receiver. It is designed in different sizes from 1 to 3 units. It is designed to be installed inside the rack. This time server has a wide screen and keyboard. It has two independent serial interfaces COM0/COM1. It has also a built-in IRIG-B protocol. Extensive development capabilities such as NTP modules for network ports are among the capabilities of this semi-modular time server. It is also possible to develop and increase ports and protocols on this time server based on the customer's request.

Quantity

GPS Clock System 6844(RC)

System 6844(RC) is a semi-modular system with integrated GPS receiver.

Basically it consists of the following components:

  • GPS radio controlled clock system 6844 consisting of
  • Housings available (optionally)
  • 1/2 19" rack (3U/42HP) for mounting into cabinets
  • 1/2 19" table-top housing
  • 1/2 19" wall housing
  • 1/1 19" rack (3U/84HP) for mounting into cabinets
  • 1 U Slim Line rack (1U/84HP) for mounting into cabinets
  • Clock board 6844 with GPS receiver
  • Display and keypad
  • 2 independent serial interfaces COM0/COM1 in RS232/RS422 for output of serial data strings, digital IRIG-B signal (B00x / IEEE C37.118-2005 (formerly IEEE 1344-1995) / AFNOR NF S87-500) or DCF77 pulse
  • Power supply
  • 2 slots for implementation of function boards or rather 2 extension slots (with bus bridge boards) for subsequent extension with function boards.

In wall housing: 1 slot for implementation of function boards or rather 1 extension slot

For output of signal outputs required in addition to those available as standard, system 6844 can be equipped with function boards. In system 6844 a maximum of two (2) function boards for system bus can be operated. When supplying system 6844 without additional function boards two extension slots (with bus bridge boards) for subsequent system extension are implemented.

Exclusion: System 6844 in wall housing. This rack version offers just one slot for function boards / bus bridge boards in connection with COM0/COM1. At customer's request system 6844 can be supplied with two slots but waiving COM0/COM1.

Applicable for rack versions 1/2 19" rack (3U/42HP) and 1/1 19" rack (3U/84HP): At time of ordering System 6844 in such rack versions additional function boards (without system bus) or prepared extension slots for such boards can be implemented.

System 6844RC / RC Functionality

By activating the Remote Function of board 6844, system 6844 turns into a system 6844RC. As a result board 6844RC can be parameterized/monitored via the hmc to be connected via a serial RS232 interface and additional internal signal outputs are available. In connection with the LAN Management Board 6844MNG the hmc connection to board 6844RC can be processed via LAN. The Remote Function performed is limited to board 6844RC only.

NTP Stratum 1 Time Server

By implementation of up to two (2) NTP LAN Board(s) 7273(RC) or NTP LAN Board(s) 7274(RC) System 6844(RC) becomes a highly accurate NTP Stratum 1 Time Server for synchronization of computers and industrial networks.

Master Clock
100 Items

Data sheet content

Time server

Type of time server
GPS
Power supplies
85 – 264VAC (50Hz / 60Hz)
power supplies feature
redundant power inputs for connection of two power sources , redundant power inputs for connection of one power sources , single power supply , DC voltage redundant power inputs
Extension slots
Over 10 extension slots
Time Server Protocol
(NTP / SNTP) , PTP , IRIG-B , DCF77 , fiber-optic signal output , RTP
Installation Method
1U fully modular subrack for 19-inch rack mounting , 3U-Version
components type
hot-plug
Master Clock
Yes

Specifications

Time server

Type of time server GPS
Power supplies 85 – 264VAC (50Hz / 60Hz)
power supplies feature redundant power inputs for connection of two power sources, redundant power inputs for connection of one power sources, single power supply, DC voltage redundant power inputs
Extension slots Over 10 extension slots
Time Server Protocol (NTP / SNTP), PTP, IRIG-B, DCF77, fiber-optic signal output, RTP
Installation Method 1U fully modular subrack for 19-inch rack mounting , 3U-Version
components type hot-plug
Master Clock Yes